For security reasons, you will be logged out in 4 minutesThis video has been hidden to respect your third-party cookie preferences.Authorise YouTube cookies when viewing videos presenting our products or services.
The Labtop coolers keep the temperature of samples on the bench at 0 °C or -20 °C. Made from polycarbonate, they accept microtubes or tubes depending on the model. The case is filled with a non-toxic gel. In certain models, the lid is also filled with gel.
Reversible cooling rack for the lab bench for 20 microtubes 1.5 ml on one side or 0.5 ml on the other side. Made from unbreakable polycarbonate, filled with a non-toxic gel, equipped with a transparent lid.
Box and racks system with cold storage blocks for refrigerating samples and keeping them at a low temperature from 0 °C to -21 °C. Ideal for enzymatic workstations, PCR stations or sample transfer.
Racks made from temperature conducting metal, designed for storage at low temperature.
They are intended for: • PCR tubes 0.2 ml individual, in strips, for PCR plates (053030); • mixed tubes (15 x 1.5 ml, 35 x 0.5 ml, 24 x 0.2 ml); • 7 x 13 tubes 0.5 ml, 55 tubes 1.5 ml or 32 tubes 5 ml.
Available as: • Complete set: each set contains 1 metal rack, 2 cooling blocks (1 °C and -10 °C) and an expanded polystyrene box. • Separate elements: each element can be bought separately.
• In high thermal conductivity alluminium • Long conservation at uniform temperature • Eliminate risk of directly immersing tubes into unstable colling media • Use in ice, dry ice and liquid nitrogen
• For 2 x 96-well PCR plates, individual tubes or in strips • Can hold 12 microtubes 0.5 ml and 8 microtubes 0.5 ml on the sides • Ideal for transferring temperature-sensitive liquids • Dimensions: 157 x 165 x 25.4 mm
• Maintain the thermo-sensitive samples temperature stable at 4 ° C for 4 hours • Change color from green to yellow or purple to pink as it warms • Supplied with lid • The contained gel is nontoxic and non-hazardous
PCR Racks: • Dim. (mm) 44 x 99 x 141 with lid / 38 x 99 x 141 without lid • PCR Version for 96 plates or strips or PCR 0.2 ml microtubes(8 x 12 emplacements) • qPCR Version for 64 Corbett Rotor-Genetubes, or 16 tubes 0.2 ml and 4 tubes 0.5 ml
Racks for tubes 0.5, 1.5 or 2 ml: • Dim. (mm): 70 x 105 x 146 with lid / 64 x 105 x 146 without lid • For 24 tubes (6 x 4 emplacements)
• Keeps the temperature at 0 °C for 4 hours • Can also be used as a PCR preparation station • Keeps the samples on the lab bench without degradation • Made from Durastar polymer with a cooling gel • Simply place in a refrigerator at night and it is ready to use • Capacity: side 1: 36 microtubes of 1.5/2 ml - side 2: 12 microtubes 1.5/2 ml + 1 x 96-well PCR plate or strips of 12 tubes 0.2 ml • Dimensions: 14.3 x 14.3 x 6.4 cm • Weight: 0.9 kg
• Container for cryopreservation and recovery, suitable for 18 x 1-2 ml tubes • Requires Isopropyl alcohol • 1 °C/min cooling rate • ø x h: 117 x 86 mm • Screw cap
• Freezing system without alcohol or refrigerant, no extra cost, no maintenance, no waste • Cells Freezing at -1 °C/minute when placed in a freezer at -80 °C Compatible with all cell types (stem cells, primary cells, PBMC, insect cells, yeast, and others) • Thermally conductive alloy core and insulating outer coating for constant cooling and high reproducibility • Symmetrical design, uniform tube freezing • Can be used after only 5 minutes • All tube slots must be filled for homogeneous freezing
• Made of aluminium alloy with high thermal conductivity • Ensure uniform temperature maintenance for all samples • No direct contact with the ice: no contamination guaranteed • Can be used in an ice tray, on dry ice, in liquid nitrogen, in an incubator or in an oven, with the CoolBoxes • Desired temperature reached quickly • Cleanable with any type of disinfectant and detergent including RNase away • Can be used from -196 °C to +100 °C • Autoclavables
• Benchtop system for cooling or freezing samples without ice, electricity or batteries • Composed of a base, an isothermal cartridge and a lid • Suitable for different sample formats and Temperatures • Compatible with dry ice, CoolRack or CoolSink
• Thermoconductive plate for uniform temperature distribution • Compatible with ice, dry ice, liquid nitrogen, water baths • Usable from -196 °C to +100 °C • The XT96F and XT 96U Models are compatible with coolBox XT
• Thermal glass microbeads • For use in water/dry baths, or to cool samples • Reduce sample contamination in applications requiring water and ice • Support tubes and bottles eliminating the need for floating racks or Weight • Autoclavable, solvent resistant • Even distribution of temperature by tight surrounding of tubes and bottles
• Filled with insulating gel • Ideal for controlled sample freezing and longer temperature retention reagents • Polycarbonate construction with rubber non-slip feet<< • Temperature retention graph supplied with each model • Gridded and keyed one-position lids
• In aluminium • Suitable for 1 x 96-well PCR plate, 6 x 1.5 ml or 2 ml microtubes, and 8 x 0.5 ml microtubes • Reliable, constant and stable cooling • Autoclavable • Dimensions L x W x H (mm) : 35 x 108 x 114